RESET Autotrol 460 Timer Regenerating EVERY NIGHT

TOTAL 460 TIMER PROGRAM RESET
* 1. Record your Hardness and Capacity settings
* 2. Disconnect power
* 3. Jumper both pins 'A' and 'B'
* 4. Reconnect power for at least 10 seconds
* 5. Disconnect Power
* 6. Remove Jumpers and return them to 'time' and 'spare'
* 7. Reconnect power and restore your hardness and capacity settings
* Result is # days since regeneration and gallons used are '0'
* Average daily usage is hex 64 or decimal 100 gallons
The REASON you would RESET your timer is IF the unit is Regenerating EVERY NIGHT. This happens when the "program" is "averaging" your daily use based on the last 30 days, and you had an unusually HIGH USAGE day during that period. A Reset should solve this problem. If not, it may be time to replace the Timer Assembly.